Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
Braz. dent. j ; 31(5): 458-465, Sept.-Oct. 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132332

ABSTRACT

Abstract This study aims to evaluate the post-extraction alveolar bone reconstruction amongst 12 patients exhibiting loss of buccal bone plate in a tooth of the anterior region of the maxilla using the prosthetically-driven alveolar reconstruction technique (PDAR). In PDAR, a partial fixed provisional prosthesis (PFPP [conventional or adhesive]) with a specially designed pontic maintains the clot in a mechanically stable position during alveolar regeneration. Moreover, the pontic design, in hourglass shape and located in the subgingival area, also prevents gingival margins from collapsing. Gingival recession was evaluated through the 6-month healing period. Cone beam computed tomography (CBCT) was performed 1 month before and 8 months after PDAR treatment. For the primary outcome, in the panoramic imaging, the central area of bone defect in each tooth was selected for linear measurements. Measurements of the vertical buccal bone gain and the gain in thickness in the alveolar bone crest were obtained 8 months after PDAR. Descriptive statistics and intraclass correlation coefficient analysis were conducted. After treatment, all patients showed bone formation (a mean vertical gain of 7.1±3.7 mm, associated with a horizontal mean gain of 4.5±1.4 mm in the alveolar bone crest). The intraclass correlation coefficient for the measurements performed using CBCT was 0.999. No gingival recession, greater than 1 mm, was observed. Lower-morbidity procedures without the use of biomaterials may be a useful in post-extraction alveolar ridge regeneration and/or preservation. PDAR promoted alveolar bone formation without flaps, grafts and membranes.


Resumo Este estudo teve como objetivo avaliar a reconstrução do osso alveolar após extração em 12 pacientes com perda da tábua óssea vestibular em dentes na região anterior da maxila usando a técnica da reconstrução alveolar proteticamente guiada (RAPG). Na RAPG, uma prótese parcial fixa provisória (PPFP [convencional ou adesiva]) com um pôntico com design específico mantém o coágulo numa posição mecanicamente estável. Além disso, o design do pôntico, com formato de ampulheta e localizado na área subgengival, também previne o colapso das margens gengivais. A recessão gengival foi avaliada durante o período de cicatrização de 6 meses. Tomografias computadorizadas cone beam (TCCB) foram feitas 1 mês antes e 8 meses após o tratamento com a RAPG. Para o desfecho primário, nas imagens panorâmicas, a área central do defeito ósseo em cada dente foi selecionada para as medições lineares. As medições do ganho vertical ósseo vestibular e do ganho em espessura na crista óssea alveolar foram realizadas. A análise estística descritiva e a análise do coeficiente de correlação intraclasse forma realizados. Após o tratamento, todos os pacientes apresentaram formação óssea (ganho vertical médio de 7,1±3,7 mm, associado a ganho horizontal médio de 4,5±1,4 mm na crista óssea alveolar). O coeficiente de correlação intraclasse foi de 0,999. Nenhuma retração gengival acima de 1 mm foi observada. Procedimentos com baixa morbidade sem o uso de biomateriais podem ser úteis na regeneração/preservação do rebordo após as extrações. A RAPG promove a formação do osso alveolar sem o uso de retalhos, enxertos e membranas.


Subject(s)
Humans , Alveolar Bone Loss/diagnostic imaging , Tooth Socket , Tooth Extraction , Retrospective Studies , Cone-Beam Computed Tomography , Alveolar Process/surgery , Alveolar Process/diagnostic imaging , Maxilla
2.
Rev. bras. odontol ; 73(1): 84-88, Jan.-Mar. 2016. ilus
Article in Portuguese | LILACS | ID: biblio-844006

ABSTRACT

O objetivo deste trabalho é relatar um caso clínico de implante imediato pós-exodontia na região anterior da maxila. O caso apresentado seguiu o seguinte protocolo de tratamento clínico: diagnóstico da necessidade de exodontia, sondagem óssea; cirurgia reversa em modelo de gesso para a confecção de um pilar de zircônia e uma restauração provisória, exodontia; instalação do implante; enxerto ósseo aloplástico; instalação do pilar de zircônia e da restauração provisória. Após seis meses foi realizada a moldagem do pilar preparado para a confecção da restauração definitiva. Os resultados obtidos preencheram os requisitos estéticos, funcionais e biológicos em função dos corretos diagnósticos, planejamento e execução do caso.


The aim of this work is to present a clinical case of immediate implant in a fresh extraction socket in the maxillary anterior region. The case was treated following the subsequent clinical treatment protocol: diagnosis of dental extraction necessity; reverse surgery in a cast model for the fabrication of a zirconia abutment and a temporary restoration; tooth extraction; alloplastic bone graft; implant placement; installation of the zirconia abutment and the temporary restoration. After a 6-month healing period, an impression of the prepared abutment was done for the production of the definitive restoration. The results met the aesthetic, functional and biological requirements due to the correct diagnosis, planning and execution of the case.

3.
ImplantNews ; 11(6a): 148-152, 2014. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-733632

ABSTRACT

Objetivo: avaliar a prevalência das medidas dos ângulos formados entre a parede medial e lateral do seio maxilar em seu terço inferior, e verificar a correlação entre os ângulos medidos e sua localização anatômica específica em áreas de dentes posteriores. Material e métodos: foram selecionados 64 cortes parasagitais em 25 exames tomográficos de uma amostra de pacientes uni ou bilateralmente desdentados, registrados para atendimento na Clínica de Implantologia Oral da Universidade do Grande Rio entre 1998 e 2004. Depois, os cortes foram digitalizados por um único operador, com cobertura transparente e em resolução 4.800 dpi. Os ângulos dos assoalhos dos seios maxilares (θ) foram medidos traçando-se linhas retas tangenciais às paredes medial e lateral, e separando sua distribuição por sítios posteriores (primeiros pré-molares, segundo pré-molares, primeiro molares e segundos molares), proporcionando três grupos: grupo 1 (θ ≤ 30º); grupo 2 (30º≤ θ ≤ 60º) e grupo 3 (> 60º). O teste qui-quadrado foi usado para avaliar a prevalência dos ângulos medidos e sua correlação com a localização anatômica, e o teste Anova para avaliar a correlação entre as médias dos ângulos mensurados e a localização anatômica. Resultados: os ângulos obtusos (grupo3) prevaleceram significativamente em 65,6% dos cortes parassagitais avaliados (p<0,01)...


Subject(s)
Dental Implantation , Diagnostic Imaging , Maxillary Sinus , Risk Factors , Tomography
4.
Dent. press implantol ; 7(2): 60-66, Apr.-June 2013.
Article in Portuguese | LILACS, BBO | ID: lil-714112

ABSTRACT

Introdução: a Ciência dos Materiais hoje possui importante destaque na Odontologia, uma vez que os biomateriais envolvidos apresentam características específicas, resultando em uma aplicação previsível. Dentro da Implantodontia, pode-se destacar os biomateriais, as membranas e as superfícies dos implantes. É de fundamental importância o conhecimento das características físico-químicas dos biomateriais para uma correta escolha, que proporcione um resultado biológico específico. Assim, a análise de propriedades, tais como cristalinidade, tamanho de partícula, porosidade e área superficial específica, é crucial para a compreensão de seu desempenho in vivo. Superfícies de implantes também têm sido desenvolvidas com o objetivo de melhorar o processo de osseointegração em áreas com quantidade e/ou qualidade óssea pobre. Objetivo: o presente trabalho tem por objetivo fazer uma revisão de literatura sobre a importância da Ciência dos Materiais no desenvolvimento dos biomateriais utilizados em Implantodontia.


Introduction: The science of materials has today been with an emphasis important in dentistry, since the biomaterials involved have specific characteristics, resulting in a predictable application. In the implantology may be emphasized biomaterials, membranes and surfaces of the implants. It is of fundamental importance to study the physicochemical characteristics of biomaterials for a correct choice that provides a specific biological outcome. Therefore, analysis of properties such as crystallinity, particle size, porosity, and specific surface area is crucial to understanding its in vivo performance. Implant surfaces also have been developed to improved osseointegration process in areas with poor quantity or quality of bone. The aim of this study is make a review about the literature of materials science developments in the biomaterials used in implantology.


Subject(s)
Biocompatible Materials , Dental Implantation , Membranes, Artificial , Brazil , Surface Properties
5.
Article in Portuguese | LILACS, BBO | ID: lil-618568

ABSTRACT

Para o sucesso e satisfação do paciente no tratamento com implantes, além da necessária e rigorosa avaliação médica e clínica, deve-se prestar especial atenção a alguns aspectos diretamente relacionados ao procedimento cirúrgico na cavidade oral. Fatores como a avaliação da densidade óssea, do volume vestíbulo-lingual/palatino e da altura óssea do sítio selecionado, a localização de estruturas anatômicas nobres, principalmente o canal mandibular e o seio maxilar, são fundamentais para o aprimoramento do diagnóstico. Para essa avaliação, algumas técnicas radiográficas têm sido indicadas. Cabe ao cirurgião-dentista adquirir conhecimento e experiência clínica para a seleção do método mais eficaz, levando em consideração o custo financeiro, a dose de radiação absorvida pelo paciente e a eficácia da informação obtida. O objetivo deste estudo é contribuir para o entendimento das técnicas radiográficas normalmente utilizadas, apresentando suas indicações, vantagens e limitações.


Besides a strict medical and clinical evaluation, implant therapy should contemplate some aspects directly related to the surgical procedures. Factors such as bone density, volume and height at the implant site, the precise position of vital structures, namely mandibular canal and maxillary sinus, are fundamental for diagnostics. Some radiographic techniques have been indicated for these purposes, allowing the clinician to obtain knowledge and clinical experience for the best method, taking into account the costs, the radiation doses taken by patients and the efficacy of the acquired information. The aim of the present study is for contribute to the understanding of the present radiographic methods, their indications, advantages, and limitations.


Subject(s)
Dental Implants , Osseointegration , Tomography , Tomography/methods
6.
ImplantNews ; 8(2): 239-243, 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-599204

ABSTRACT

A presença de microfenda entre o implante e o pilar protético pode ser responsável pelo acúmulo do biofilme peri-implantar, composto por várias cepas bacterianas. Quando descrito como fator etiológico de processos inflamatórios, apresentam como consequência a desorganização dos tecidos, podendo interferir na saúde peri-implantar a longo prazo. O objetivo deste estudo foi avaliar se a microfenda existente entre implantes com plataforma cone-morse e pilares protéticos permitiria a ocorrência de infiltração de uma cepa bacteriana específica. Foram utilizados 30 conjuntos implantes/pilares protéticos de dois sistemas de implantes com interface tipo cone-morse comercializados no Brasil. A amostra foi dividida em três grupos com dez corpos de prova cada: implantes Neodent com pilares protéticos Neodent, implantes Ankylos com pilares protéticos Ankylos e implantes Ankylos com pilares protéticos Neodent. O espaço interno dos implantes foi inoculado com 0,1 μl de uma suspensão de Escherichia coli. Em seguida, os pilares foram instalados utilizando-se o torque recomendado pelos fabricantes. Os corpos de prova foram então mergulhados em um meio de cultura MacConkey para análise de turvamento, comprovando a infiltração pela microfenda. A leitura após a inoculação foi realizada em um, dois, cinco, sete e 14 dias. Os resultados demonstraram que nenhum dos corpos de prova apresentou turvamento do meio de cultura, sendo a viabilidade da bactéria comprovada através de teste controle positivo. Concluiu-se que as interfaces tipo cone-morse estudadas, impediram a migração de Escherichia coli entre componentes de prótese e os implantes utilizados.


The presence of microgap between dental implant and prosthetic abutment may be responsible for the accumulation of peri-implant biofilm, composed of several bacterial strains. When described as etiological factor of inflammatory processes they trigger tissue disruption and can interfere with the long-term periimplant health. The aim of this study was to assess whether the microgap between Morse Taper platform implants and prosthetic abutment allow the occurrence of infiltration of a specific bacterial strain. It was used 30 sets implants/prosthetic abutment of two implant systems with Morse Taper interface marketed in Brazil. The sample was divided into 3 groups with 10 samples each: Neodent implants and prosthetic abutments, Ankylos implants with respective prosthetic abutments, and Ankylos implants with Neodent prosthetic abutments. The implant inner chamber was inoculated with 0.1 μl of Escherichia coli suspension, before the abutment recommended tightening by each manufacturer. Samples were then immersed in a culture medium for analysis of MacConkey muddiness for analysis of cloudiness, indicating infiltration at the microgap. Measurements after inoculation were performed at 1, 2, 5, 7, and 14 days. The results showed that none of the samples presented cloudiness in the culture medium, with the viability of the bacteria demonstrated by positive control tests. It was concluded that the Morse Taper interfaces systems studied prevented the migration of E. coli between the prosthetic abutment and implants used.


Subject(s)
Dental Implants , Dental Leakage , Osseointegration
7.
ImplantNews ; 7(6): 801-810, 2010. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-599213

ABSTRACT

Esta pesquisa objetivou avaliar a capacidade de infiltração bacteriana e a desadaptação vertical ao longo da interface implante/pilar protético e classificar a desadaptação vertical e horizontal nos pontos externos da interface, segundo uma nova proposta. Material e métodos: 40 implantes de cinco sistemas nacionais foram inoculados com Escherichia coli e colocados em meio de cultura para observação da infiltração em um, dois, cinco, sete e 14 dias pela turvação do mesmo. Posteriormente, as amostras foram embutidas e desgastadas para avaliação da desadaptação ao longo de toda a interface em microscopia eletrônica de varredura. Resultados: somente um dos sistemas apresentou infiltração bacteriana em 25% das amostras. Os menores valores da desadaptação foram para o sistema Neodent (0,51 μm ± 0,39) e Dentoflex (1,44 μm ± 0,73), seguidos do Titanium Fix (1,88 μm ± 1,28), SIN (2,46 μm ± 3,38) e Conexão (2,68 μm ± 3,02). Os Tipos II e IV da classificação para o desajuste vertical e horizontal foram predominantes. Concluiu-se que todos os grupos apresentaram desadaptação ao longo da interface em pelo menos um dos seis pontos avaliados entre implante e pilar protético. O aumento da desadaptação, nesta interface, não é o único fator determinante para a ocorrência do infiltrado bacteriano, devendo-se levar em consideração a extensão da área de acoplamento na interface e quanto à classificação da desadaptação, o Tipo I, que é a desejada, só ocorreu em 7,5% das amostras.


This study aims to access bacterial leakage capacity and vertical misfit along the prosthetic implantabutment interface and classify the vertical and horizontal misfits at the external interface points, according to a new proposal. Materials and methods: 40 implants of five commercial implant manufacturers were inoculated with Escherichia coli and placed in a culture medium to observe the leakage within 1, 2, 5, 7, and 14 days through media cloud. After, the samples were fitted and the implant-abutment interface evaluated by scanning electron microscopy. Results: Only one of the systems showed bacterial infiltration in 25% of the samples. The lowest values of misfit were presented by Neodent- 0.51 ± 0.39 μm and Dentoflex systems- 1.44 ± 0.73 μm, followed by Titanium Fix - 1.88 ± 1.28 μm; SIN 2.46 ± 3.38 μm and Conexão - 2.68 ± 3.02 μm. Types II and IV of the classification for the vertical and horizontal misfits were predominant. The conclusion was that all groups presented misfit along the interface of at least one of the six points evaluated between the implant and the prosthetic abutment. Increased misfit in the interface is not the only determining factor for occurrence of the bacterial leakage. Also, it must be taken into account the extent of the coupling interface, and concerning the classification of the misfit, type I, which is the most desired, occurred only in 7.5% of the samples.


Subject(s)
Dental Implants/microbiology , Osseointegration , Prosthesis Fitting
8.
Rev. bras. odontol ; 66(2): 244-249, jul.-dez. 2009. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-562673

ABSTRACT

Considerações estéticas em Implantodontia têm sido motivo de diversos estudos e publicações nos últimos 15 anos, atentando-se para a existência de diversos parâmetros que devem ser criteriosamente analisados durante a etapa de planejamento para a instalação de implantes osseointegrados. Alguns fatores se destacam na busca do resultado estético ideal, como o posicionamento tridimensional adequado do implante, anatomia do rebordo alveolar, fenótipo periodontal, tipo de material restaurador, perfil emergente da prótese, dimensões do espaço edêntulo disponíveis e o momento de instalação do implante.


Subject(s)
Dental Implantation, Endosseous , Esthetics, Dental , Patient Care Planning , Socioeconomic Factors , Treatment Outcome
9.
ImplantNews ; 6(2): 169-176, mar.-abr. 2009.
Article in Portuguese | LILACS, BBO | ID: lil-523914

ABSTRACT

Existem diversos raspadores ósseos comercialmente disponíveis, apresentando diferentes características e resultados clínicos. Na literatura atual, existem poucos trabalhos que analisem as características estruturais e do projeto dos diferentes raspadores e que as relacionem à eficácia dos mesmos. O objetivo deste trabalho foi analisar os projetos de nove diferentes raspadores ósseos e as características estruturais do aço das lâminas de corte, correlacionando com o desempenho in vitro. O presente trabalho avaliou o ângulo de corte da ponta ativa; a distância do acesso por onde o osso é coletado; a dimensão do contorno de grãos, o grau de dureza e a composição química do metal da lâmina do raspador; além da eficácia do raspador num teste in vitro. Com cada um dos raspadores ósseos, um cirurgião-dentista realizou 20 golpes de raspagem ao longo de um segmento de fêmur bovino de 6 cm. As partículas de osso coletadas foram pesadas em uma balança de precisão. Os resultados demonstraram que tanto a abertura da ponta ativa, quanto o ângulo de corte da ponta ativa, que são características dos projetos dos raspadores ósseos, não influenciaram na quantidade de osso raspado. Entretanto, as características estruturais das lâminas dos raspadores ósseos (diâmetro médio de grão, dureza Vickers e composição química) influenciaram na quantidade de osso raspado. A análise estrutural dos raspadores ósseos é uma importante ferramenta para validar seu uso e oferecer maior conforto e segurança aos pacientes e cirurgiões.


There are many commercially available bone scrapers presenting different characteristics and different clinical results. In the current literature, there are few articles analyzing the structural and design characteristics related to the effectiveness of bone scrapers. The aim of the present study was to analyze the design of nine different commercially available bone scrapers, as well as the structural characteristics of their stainless steel blades, as well as the in vitro performance of these instruments. With each bone scraper, one dentist performed 20 strokes in a 6cm bovine femur block. The bone particles harvested were weighted using a precision weight. The results of the different scrapers show that both the opening and the cutting angles of the cutting end, which are characteristics of the bone scrapers projects, did not influence the quantity of bone harvested. On the other hand, structural characteristics of these blades (average diameter of the grain, Vickers hardness, and chemical composition) influenced in the quantity of the harvested bone. The structural analyses of scrapers are an important tool in the validation of its use and also provide more comfort and safety for patients and surgeons.


Subject(s)
Animals , Cattle , Dental Instruments , Materials Testing , Bone and Bones
10.
ImplantNews ; 6(5): 479-483, 2009.
Article in Portuguese | LILACS, BBO | ID: lil-544250

ABSTRACT

Diversos estudos se concentram na pesquisa de biomateriais que permaneçam implantados no corpo humano de maneira satisfatória e por períodos mais longos. Considerável progresso vem ocorrendo no conhecimento dos mecanismos básicos da formação da interface entre o tecido ósseo e o biomaterial e o seu efeito na formação óssea. A cultura de células é um dos métodos empregados para estudar o comportamento celular e sua interação com as superfícies dos biomateriais no que se refere à toxicidade, adesão, proliferação e função. No entanto, estes testes são, em geral, estáticos e não conseguem reproduzir a dinâmica e a biodiversidade que um biomaterial fica sujeito quando inserido dentro de um organismo vivo. O objetivo do presente estudo foi realizar uma revisão de literatura sobre a cultura de células e sua relação com a Implantologia Oral.


Several studies have focused on the research of biomaterials that remain satisfactorily, long-term implanted in the human body. Considerable progress has occurred on the understanding of basic mechanisms regarding bone tissue-biomaterial interfaces, and your effect on bone formation as well. Cells culture is one of the methods used to study the cellular component and its interaction with biomaterial surfaces related to toxicity, attachment, proliferation, and function. However, these tests are usually static and cannot reproduce the dynamics and biodiversity that a biomaterial is prone when inserted into a living organism. The purpose of this study was to perform a literature review on the subject and their implications for oral implantology.


Subject(s)
Biocompatible Materials , Bone and Bones , Dental Implants , Osteoblasts
11.
ImplantNews ; 5(5): 505-510, set.-out. 2008. ilus
Article in Portuguese | LILACS, BBO | ID: lil-523875

ABSTRACT

Este trabalho teve como objetivo avaliar a desadaptação na interface entre o análogo de implante e o pilar protético correspondente de quatro diferentes sistemas de implantes para osseointegração e verificar a infiltração bacteriana através destas interfaces. Foram testados cinco amostras de cada sistema: 3i, Frialit, ITI e NobelBiocare, aos quais foram aplicados os torques recomendados pelos fabricantes. As medidas de desadaptação foram obtidas em três pontos com o auxílio de microscopia eletrônica de varredura, com magnificação de 1.000 vezes. Os análogos e os pilares protéticos foram acoplados após a ponta dos parafusos dos pilares serem inoculados com uma suspensão de bactérias (Escherichia coli) para verificar a capacidade das bactérias de atravessar esta interface. A análise estatística foi feita através do teste não-paramétrico de Kruskal-Wallis e do teste de Student-Newman-Keuls Os resultados mostraram um melhor ajuste para o sistema Nobel Biocare (0,51 µm ± 0,247 µm), seguido pelos sistemas 3i (3,46 µm ± 0,595 µm), Frialit (3,99 µm ± 1,505 µm) e ITI (5,54 µm ± 1,522 µm). Quanto à infiltração bacteriana, após 14 dias, os sistemas 3i e ITI apresentaram 80% dos espécimes infiltrados (n=4), Frialit (20%, n=1); e o sistema Nobel Biocare não apresentou infiltração bacteriana. A análise da infiltração microbiana através da interface de seus componentes é um método eficaz de controle da adaptação de seus componentes.


Subject(s)
Bacterial Adhesion , Dental Implants , Osseointegration , Microscopy, Electron, Scanning
12.
ImplantNews ; 5(2): 155-158, mar.-abr. 2008.
Article in Portuguese | LILACS, BBO | ID: lil-518303

ABSTRACT

O sucesso clínico de implantes dentários é orientado em parte pelas propriedades de superfície e suas interações com os tecidos circundantes e a microbiota oral. A longevidade da osseointegração dos implantes pode ser comprometida pela sobrecarga oclusal e/ou pela periimplantite induzida por biofilme bacteriano. Salienta-se também o fumo, doenças sistêmicas e a má higiene bucal como fatores predisponentes ao aumento do risco de periimplantite. O objetivo deste artigo é rever as técnicas de descontaminação da superfície de implantes osseointegráveis, utilizados na reabilitação de pacientes parcialmente ou totalmente edêntulos.


Subject(s)
Decontamination , Dental Implants , Titanium , Surface Properties
13.
Braz. dent. j ; 19(2): 159-164, 2008. ilus
Article in English | LILACS | ID: lil-484957

ABSTRACT

This article addresses diagnostic parameters that should be assessed in the treatment of extraction sockets with dental implant placement by presenting three case reports that emphasize the relevance of the amount of remaining bone walls. Diagnosis was based on the analysis of clinical and radiographic parameters (e.g.: bone defect morphology, remaining bone volume, presence of infections on the receptor site). Case 1 presents a 5-wall defect in the maxillary right central incisor region with severe root resorption, which was treated with immediate implant placement. Cases 2 and 3 present, respectively, two- and three-wall bone defects that did not have indication for immediate implants. These cases were first submitted to a guided bone regeneration (GBR) procedure with bone graft biomaterial and membrane barriers, and the implants were installed in a second surgical procedure. The analysis of the preoperative periodontal condition of the adjacent teeth and bone defect morphology is extremely important because these factors determine the choice between immediate implant or GBR treatment followed by implant installation in a subsequent intervention.


Este artigo aborda os parâmetros clínicos que devem ser observados no diagnóstico e tratamento de alvéolos de extração por meio da instalação de implantes através da apresentação de casos clínicos, enfatizando a importância do número de paredes ósseas. O diagnóstico baseou-se na análise de parâmetros clínicos e radiográficos (p. ex: morfologia do defeito ósseo, volume ósseo remanescente, presença de infecção na área receptora). O Caso 1 apresenta um defeito de 5 paredes relacionado a um incisivo central superior direito que apresentava extensa reabsorção radicular e foi tratado através da técnica de implante imediato. Os Casos 2 e 3 consistem em defeitos de 2 e 3 paredes ósseas presentes, respectivamente, que inicialmente não devem ser tratados com implantes imediatos, e, por isso, foram submetidos inicialmente ao procedimento de regeneração óssea guiada, com uso de biomateriais para enxertia e barreiras de membrana, para receberem implantes numa segunda etapa cirúrgica. A avaliação prévia das condições periodontais dos dentes adjacentes e da morfologia do defeito ósseo são extremamente importantes, uma vez que determinam se determinada área será tratada pela técnica de ROG ou pela técnica de implantes imediatos.


Subject(s)
Adult , Female , Humans , Middle Aged , Alveolar Bone Loss/diagnosis , Dental Implants , Dental Implantation, Endosseous/methods , Tooth Extraction , Tooth Socket/pathology , Alveolar Bone Loss/surgery , Bone Transplantation , Bone Matrix/transplantation , Bone Substitutes/therapeutic use , Crowns , Dental Abutments , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Follow-Up Studies , Guided Tissue Regeneration, Periodontal/methods , Incisor/injuries , Membranes, Artificial , Minerals/therapeutic use , Polytetrafluoroethylene , Root Resorption/surgery , Tooth Fractures/surgery
14.
ImplantNews ; 04(06): 659-662, Nov./Dez.2007.
Article in Portuguese | LILACS, BBO | ID: biblio-850908

ABSTRACT

As pesquisas com células ósseas representam um avanço para toda a humanidade, principalmente pelo conhecimento adquirido através dos estudos dos mecanismos envolvidos em doenças como a osteoporose, doença de Paget e artrite reumatóide. Este artigo tem como objetivo, fazer uma revisão do tema biologia óssea, descrevendo os diferentes componentes da matriz óssea, bem como suas respectivas funções.


Subject(s)
Bone Matrix , Connective Tissue Cells
15.
ImplantNews ; 4(3): 287-292, maio/jun. 2007. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-850961

ABSTRACT

O presente artigo revisa a literatura no que se refere as alternativas cirúrgicas ou não de tratamento da região posterior da mandíbula com diferentes graus de atrofia óssea. Metodologias visando as reabilitações implanto-suportadas foram destacadas assim como os riscos e os benefícios relativos a cada uma delas


Subject(s)
Humans , Alveolar Ridge Augmentation , /methods , Mandible , Mouth Rehabilitation , Prostheses and Implants , Alveolar Bone Loss , Dental Prosthesis, Implant-Supported/methods , Biocompatible Materials , Bone Regeneration , Bone Transplantation , Osteogenesis, Distraction
16.
ImplantNews ; 4(3): 303-306, maio/jun. 2007. tab
Article in Portuguese | LILACS, BBO | ID: biblio-850963

ABSTRACT

O comportamento in vivo dos biomateriais é dependente de suas características físico-químicas. O presente trabalho teve como objetivo realizar uma revisão de literatura sobre os biomateriais utilizados emenxertos ósseos, enfatizando a hidroxiapatita de origem bovina absorvível (Bio-Oss) e as suas principais características fisico-químicas


Subject(s)
Animals , Cattle , Biocompatible Materials , Bone Transplantation , Hydroxyapatites , Alveolar Ridge Augmentation/methods
17.
Rev. bras. odontol ; 64(1/2): 21-25, 2007. ilus
Article in Portuguese | LILACS, BBO | ID: lil-541846

ABSTRACT

A grande exigência estética na finalização protética nos casos de implantes instalados na região anterior tornou imprescindível o conhecimento das possíveis alterações causadas na gengiva após a instalação de próteses sobre implantes osseointegrados. A inter-relação entre as diferentes especialidades, como Periodontia, Cirurgia, Prótese e Ortodontia, possibilita a adequação prévia da área cirúrgica e a finalização estética de forma previsível. O objetivo deste estudo é descrever, avaliar e discutir as alterações, tanto estéticas quanto funcionais, do fenótipo gengival na região anterior após a cirurgia para a instalação de implantes, e assim relacionar: cor, textura, espessura, retração da margem, papila e forma do contorno da margem.


Subject(s)
Dental Implants , Dental Papilla , Gingiva , Phenotype
18.
ImplantNews ; 3(5): 487-491, set.-out. 2006.
Article in Portuguese | LILACS, BBO | ID: lil-461718

ABSTRACT

Os biomateriais vêm sendo cada vez mais utilizados na Implantodontia, atuam nos procedimentos de reconstrução do rebordo alveolar total ou parcialmente perdido como conseqüência de doenças periodontais, extrações traumáticas, cistos, tumores e traumatismos. O entendimento das características físico-químicadestes biomateriais é fundamental para a previsibilidade do seu comportamento in vivo, fornecendo ao profissional da área da saúde, conhecimentos para que estepossa escolher aquele mais adequado no processo de reconstrução dos defeitos ósseos. Este artigo tem como objetivo, por meio da revisão de literatura, identificaras principais propriedades físicas, químicas e biológicas dos biomateriais utilizados em enxerto ósseo.


Subject(s)
Biocompatible Materials , Bone Transplantation , Dental Implantation, Endosseous
19.
ImplantNews ; 3(2): 155-160, mar.-abr. 2006. ilus
Article in Portuguese | LILACS, BBO | ID: lil-457355

ABSTRACT

A meta da Implantodontia atual deve ser uma restauração implanto-suportada que esteja em harmonia com os tecidos mucoso e ósseo circundantes. O objetivo deste artigo é avaliar os fatores anatômicos, cirúrgicos, protéticos e biológicos que determinam o fenótipo gengival ao redor dos implantes osseointegrados.


Subject(s)
Humans , Gingiva , Dental Implants , Mouth Mucosa , Osseointegration , Phenotype , Esthetics, Dental
20.
Rev. bras. odontol ; 63(1/2): 61-64, 2006. ilus
Article in Portuguese | LILACS, BBO | ID: lil-438458

ABSTRACT

O espaço biológico em dentes é definido como uma barreira biológica formada por tecido epitelial e conjuntivo que veda o segmento tecidual do meio bucal. Em implantes, esse espaço biológico apresenta características semelhantes em tamanho e composição tecidual. Fatores tais como biocompatibilidade dos componentes transmucosos; contaminação deste componentes e número de retiradas e recolocações, podem interferir na integridade e saúde do espaço biológico como barreira. O objetivo deste artigo é apresentar um caso clínico de instalação de implante e provisionalização imediata, pós-exodontia na região estética, e discutir os fatores que podem influenciar a formação e a posição dessa barreira biológica


Subject(s)
Humans , Male , Adult , Esthetics, Dental , Tooth Extraction/methods , Dental Implants/methods , Periodontium , Tooth Fractures
SELECTION OF CITATIONS
SEARCH DETAIL